BU9883FV-W
Datasheet
3. Set SDA0 to 3 and SCL0 to 3 so as not to become 'Hi-Z'.
When the above conditions 1 and 2 cannot be observed, take the following countermeasures.
a) In the case when the above condition 1 cannot be observed. When SDA0 to 3 becomes 'L' at power on.
→ Control SCL0 to 3 and SDA0 to 3 as shown below, to make SCL0 to 3 and SDA0 to 3, 'H' and 'H'.
V CC
SCL
SDA
After Vcc becomes stable
t LOW
After Vcc becomes stable
t DH
t SU:DAT
t SU:DAT
Figure 59. When SCL0 to 3= 'H' and SDA0 to 3= 'L'
Figure 60. When SCL0 to 3='L' and SDA0 to 3='L'
b) In the case when the above condition 2 cannot be observed.
→ After power source becomes stable, execute software reset(Page 19).
c) In the case when the above conditions 1 and 2 cannot be observed.
→ Carry out a), and then carry out b).
● Low voltage malfunction prevention function
LVCC circuit prevents data rewrite action at low power, and prevents wrong write. At LVCC voltage (Typ. =1.2V) or below, it
prevent data rewrite.
● V CC noise countermeasures
○ Bypass capacitor
When noise or surge gets in the power source line, malfunction may occur, therefore, for removing these, it is
recommended to attach a by pass capacitor (0.1 μ F) between IC V CC OUT and GND. At that moment, attach it as close to
IC as possible. And, it is also recommended to attach a bypass capacitor between board V CC OUT and GND.
● Cautions on use
(1) Described numeric values and data are design representative values, and the values are not guaranteed.
(2) We believe that application circuit examples are recommendable, however, in actual use, confirm characteristics further
sufficiently. In the case of use by changing the fixed number of external parts, make your decision with sufficient margin
in consideration of static characteristics and transition characteristics and fluctuations of external parts and our LSI.
(3) Absolute maximum ratings
If the absolute maximum ratings such as impressed voltage and action temperature range and so forth are exceeded,
LSI may be destructed. Do not impress voltage and temperature exceeding the absolute maximum ratings. In the case
of fear exceeding the absolute maximum ratings, take physical safety countermeasures such as fuses, and see to it
that conditions exceeding the absolute maximum ratings should not be impressed to LSI.
(4) GND electric potential
Set the voltage of GND terminal lowest at any action condition. Make sure that each terminal voltage is lower than that
of GND terminal.
(5) Terminal design
In consideration of permissible loss in actual use condition, carry out heat design with sufficient margin.
(6) Terminal to terminal shortcircuit and wrong packaging
When to package LSI onto a board, pay sufficient attention to LSI direction and displacement. Wrong packaging may
destruct LSI. And in the case of shortcircuit between LSI terminals and terminals and power source, terminal and GND
owing to foreign matter, LSI may be destructed.
(7) Use in a strong electromagnetic field may cause malfunction, therefore, evaluate design sufficiently.
Status of this document
The Japanese version of this document is formal specification. A customer may use this translation version only for a reference
to help reading the formal version.
If there are any differences in translation version of this document formal version takes priority.
www.rohm.com
? 2012 ROHM Co., Ltd. All rights reserved.
TSZ22111 ? 15 ? 001
23/25
TSZ02201-0R2R0G100420-1-2
31.AUG.2012 Rev.001